Model No:CEI-AWD-KJ09
Anesthesia workstations play a pivotal role in ensuring the safety and well-being of patients undergoing surgical procedures. These sophisticated devices are essential components of modern operating rooms, providing anesthesiologists with the tools and technologies needed to administer anesthesia and monitor patients throughout surgery. In this article, we will delve into the key features and functions of anesthesia workstations, highlighting their importance in contemporary healthcare settings. Anesthesia workstations are equipped with advanced gas delivery systems that precisely administer a mixture of gases, including oxygen, nitrous oxide, and inhalation anesthetics. These systems are designed to maintain a controlled and consistent flow of gases to ensure the patient receives the appropriate anesthesia levels. Patient safety is a top priority, and anesthesia workstations are designed with numerous safety features. These may include alarms for low oxygen levels, high or low pressure in the breathing circuit, and system malfunctions. Redundant safety mechanisms are often in place to provide an added layer of protection. Anesthesia workstations are indispensable tools in the realm of modern healthcare, contributing significantly to the safety and success of surgical interventions. The integration of advanced technologies and user-friendly interfaces empowers healthcare professionals to deliver precise anesthesia, monitor patients effectively, and respond promptly to changing conditions. As technology continues to advance, anesthesia workstations will likely play an increasingly vital role in optimizing patient outcomes and improving the overall efficiency of surgical procedures.
Anesthesia Workstation with its ergonomic design, integrates a concise and smooth structure and high mobility.
The microcomputer-controlled Ventilator adopts exported sensors and other components. Its scientific and proper design as well as rigorous production process are what demonstrate the inner quality of the Product.
Mechanical ventilation is made secure and visible by the folded respiratory bellows and the security of air supply is guaranteed by pneumatic transmission and measurement system. With multiple modern technologies applied, the Anesthesia Workstation is both outstanding in performance and versatile in functions.
High-definition five tube flowmeter (oxygen, nitrous oxide, and air) are designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
Reliable pneumatic transmission system.
Part of Anesthesia Workstation
Main Body : High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of application : Adult and Child
Gas source : O2, N2O, Air: 0.28~0.6MPa
Flow meter : O2: 0.05~1.0L/min 1.1~10L/min
N20: 0.05~1.0L/min 1.1~10L/min
Air : 0.05~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply : 25~75L/min
Low oxygen pressure alarm : There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer : It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.
Respiratory Circuit : Working mode: all-close, semi-close, semi-open
APL: ?12.5kPa
Respiratory Bellows : Bellows for adults, tidal volume range : 0~1500 ml
Bellows for children, tidal volume range : 0~300 ml
Anyone can be chosen for application
Part of Ventilator
Display Mode : High-definition 10.4” TFT color LCD screen display
Ventilation Mode : VCV, PCV, SIMV, MANUAL
Ventilation Functions : PEEP, SIGH, IP, IRV, Standby
Ventilation Parameters : Tidal volume 20~1600 ml
Rate 2~99 bpm
SIMV rate 2~20 bpm
I:E 4:1~1:8
Inspiratory trigger pressure : -10~20cmH2O
Oxygen Concentration alarm : Upper limit setting range 21%~99%
Low limit setting range 18%~80%
Airway pressure alarm : upper limit setting range 5~60cmH2O
low limit setting range 0~50cmH2O
Per-minute ventilation volume alarmupper limit setting range 1~20L/min
low limit setting range 0~19L/min
Respiratory rate : upper limit setting range 10~99bpm
low limit setting range 0~50bpm
Tidal volume : upper limit setting range 10~1500ml
low limit setting range 0~1400ml