The Ventilator Vertical stands out as a revolutionary concept, bringing enhanced efficiency and space optimization to ventilation systems. This comprehensive guide explores the features, benefits, and applications of Ventilator Vertical, shedding light on its role in creating healthier and more sustainable indoor environments. The core of Ventilator Vertical systems lies in their vertical ducts, strategically placed to facilitate the natural movement of air. These ducts are designed to optimize airflow and ensure an even distribution throughout the space. Ventilator Vertical represents a paradigm shift in the world of ventilation, offering a holistic solution that addresses indoor air quality, energy efficiency, and space optimization. As the demand for sustainable and intelligent building systems grows, Ventilator Vertical emerges as a promising choice for architects, engineers, and building owners looking to create healthier and more efficient indoor environments.
Ventilator Vertical is a multi-functional Ventilator adopting pneumatic, electronic control and microcomputer technology. Exported components are utilized to guarantee operational stability and reliability. With color screen (TEF) to display various measuring and configuration parameters, the device is very suitable for respiratory treatment, applicable for medical, surgical and gynecological departments, the department of pediatrics, first aid, and ICU departments of hospitals at different levels.
Ventilator
Display Mode : High-definition 10.4” TFT color LCD screen display
Ventilation Mode : VCV,PCV,SIMV,PSV,PSV+SIMV,CPAP
Ventilation Function : PEEP,SIGH, IRV, IP,Standby
Ventilation Parameters :
Tidal volume 20~1800 ml
Rate 2~120bpm
SIMV rate 2~120bpm
I:E 4:1~1:8
SIGH 1.5 times the inspiratory time (60-120 adjustable)
Inspiratory platform 0~50%
Oxygen concentration 21%~99%
Parameters for ventilation monitoring
Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure-volume loop
Security Alarm System
Oxygen Concentration alarm : Upper limit setting range 21%~99%
Low limit setting range 18%~80%
Airway pressure alarm : Upper limit setting range 5~60 cmH2O
Low limit setting range 0~50 cmH2O
Per-minute ventilation volume alarm : Upper limit setting range 1~20L/min
Low limit setting range 0~19L/min
Tidal volume : Upper limit setting range 10~1800ml
Low limit setting range 0~1700ml
Respiratory rate : Upper limit setting range 10~99bpm
Low limit setting range 0~50bpm
Sustained high-pressure alarm : It will give alarm when stress have consistently been higher than 30 cm H2O
Suffocation alarm : Power alarm
Low pressure of oxygen alarm : Intubation off alarm
Low pressure of Air alarm : Battery voltage alarm
Power : AC 220V 50Hz (UPS, Storage battery)